PILOT PMAC811 Low voltage Intelligent AC Motor Protection Controller relay with CT

FOB Reference Price:Get Latest Price
  • >=1 Sets
    $0.01
Shipping:
Support Sea freight
Lead Time:
Quantity(Sets) 1 - 50 >50
Est. Time(days) 20 Negotiable
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
PILOT
Model Number:
PMAC811
Microscope Theory:
Motor Protection Controller
Usage:
Protective
Size:
117mm*104mm*72mm
Protect Feature:
Epoxy
Contact Load:
Low Power
Application:
for low voltage motor applications
Voltage:
AC380 / 690V
Current:
1 ~ 400A (<132KW); **A/5A or **A/1A (≥132KW)
Product name:
motor protection controller
Frequency:
50 / 60Hz
communication:
RS485, modbus-rtu
Port:
AO, RS485,
replay output:
5 channel
additional:
DI, DO, AI
Power / Electricity accuracy:
±1%
Packaging & Delivery
Lead Time :
Quantity(Sets) 1 - 50 >50
Est. Time(days) 20 To be negotiated

PILOT PMAC811 Low voltage Intelligent AC Motor Protection Controller relay with CT

 

 

 

Feature

 

Ø Integrated motor protection, control, measurement, metering, management and communication among PMAC811 series intelligent motor protection controller
Ø Widely used in petroleum, chemical, electricity, metallurgy, steel, paper, textile, cement, municipal industrials etc…
Ø Suitable for low voltage motor applications with AC380 / 690V rated voltage, 50 / 60Hz
Ø Replace discrete components in the motor control center (MCC), greatly simplify the motor control loop, improve the reliability and stability and reduce the comprehensive cost
Ø Adopt modular structure design with small size, compact structure, strong versatility, easy installation and operation
Ø Record 256 Events, accurately trace back to the failure reason
Ø The AC contactor can be blocked when has extremely large short-circuit current, achieve complete protection of the MCC circuit by driving circuit breaker by the product internal relay
Ø With strong and reliable RS485 communication interface, can undertake AC380V strong electricity without damage

 

 

 

 

 

Function

 

MeasurementThree phase current, ground current, three phase current imbalance rate, average current, positive sequence current, negative sequence current, three phase line voltage, frequency, power factor, active power, reactive power, active energy, positive sequence voltage, negative sequence voltage, three phase voltage unbalance rate, three phase current harmonics, three phase voltage harmonics etc.
ProtectionStarting overtime, starting overcurrent, overload, tE time, stall, phase failure, imbalance, quick-break, grounding, underload/power, external failure, under/overvoltage, Phase sequence, TV disconnection, negative sequence protection etc.
MaintenanceRecord 256 recent event information (32 events of each type, total 8 types), record event type, occurrence time, characteristic quantity; cumulative total running/stop time of motor, current running/stop time, total stop and trip times, maximum starting time/current etc.
ControlCommunication control, dangling power control, restart controlled by time-shared or in batch
Communication2 channel RS485 interfaces, Modbus-RTU communication protocol. Support to expand Profibus-DP communication, DI/DO quantity, AI, temperature detection etc.

 

 

 

Specification

 

 

 

 

Dimension & Installation

 

 

 

 

Order Information

 

 

Notes: 

 

Ø Standard 1 channel Modbus-RTU communication, tE time and single phase grounding protection (internal vector & algorithm)
Ø Three phase CT (1-400) A is a direct connection, 5P10 protection level

Ø When the rated current of the motor is over 400A, using indirect connection, that is, the product provides a standard 5A (1A) of CT+**A/5A (**A/1A) . E.g. , 500A / 5A with 3 CTs for each motor

Ø Pease specify the optional function when Profibus-DP communication, additional DI / DO, AI, temperature detection are needed. 

 

 

Example: PMAC811-A-25A-AO indicates color screen display, 5 channel relay output, harmonic, fault record, 25A rated current CT, Standard 1 channel modbus communication and 1 channel 4-20mA AO

 

 

 

Order Information

 

1) 1A, 5A, 25A, 100A CT Specification: (unit:mm)

 

 

 

 

 

1) 250A, 400A CT Specification: (unit: mm)

 

 

 

 

Connection: The secondary side outlet of yellow, green, red, black cables separately represent the secondary outlet and common ports of A, B, C phase currents. Do not ground the common port. The length of the secondary side cable is 1 meter.